Varmeca 30, Variable speed motor or geared motor – Watson-Marlow Varmeca 30 User Manual
Page 22

56
INSTALLATION AND MAINTENANCE
VARMECA 30
Variable speed motor or geared motor
CONNECTIONS
LEROY-SOMER
3776 en - 07.2007 / h
3.5.2.3 - 3-phase AC power supply in accordance with safety standard EN954-1 - category 2 or 3 with use of safety input
SDI2 redundantly with logic input DI2
QS: Fused isolator: QS must be opened before any intervention on the electrical parts of the drive or motor.
AU: Emergency stop button.
KA: Relays
Optional braking resistor. Dissipates the active power returned by the motor onto the drive DC bus in the event of a driving
machine.
Using the safety input means the motor can be stopped in freewheel mode without using a line contactor. The drive’s internal
principles are sufficiently safe to perform a stop using the safety input directly (category 1 of EN954-1).
Duplication of the stop command on a logic input enables use of the internal drive redundancy to perform a freewheel stop
(application of category 3 principles in accordance with EN954 for the part relating to the drive).