beautypg.com

Varmeca 30, Variable speed motor or geared motor, 2 - control terminal blocks – Watson-Marlow Varmeca 30 User Manual

Page 16: Leroy-somer

background image

50

INSTALLATION AND MAINTENANCE

VARMECA 30

Variable speed motor or geared motor

CONNECTIONS

LEROY-SOMER

3776 en - 07.2007 / h

3.2 - Control terminal blocks

• Check that the terminal block has been removed
from its fixed holder (unplugged) before making

any connections, so as to avoid putting pressure on the
card.
• The VARMECA has a positive logic configuration. Using
a drive with a control system which has a different
control logic may cause unwanted starting of the motor.
• The control circuits in the drive are isolated from the
power circuits by single insulation (IEC 664-1).

The installer must ensure that the external control
circuits are isolated against any human contact.
• If the control circuits need to be connected to circuits
conforming to SELV safety requirements, additional
insulation must be inserted to maintain the SELV
classification.

Removable screw terminal block:
- Tightening torque = 0.3 N.m
- Max. cross-section = 1.5 mm

2

VMA

terminal

33/34

VMA

terminal

31/32

Designation

Function

Characteristics

1

1

10V

+10V analogue internal source

Accuracy

± 2%

Maximum output current

30 mA

2

2

ADI1

Analogue or logic
input 1

Assignment in standard
configuration: 0-10V speed
reference

Voltage input

Full scale voltage

10 V ± 2%

Input impedance

95 k

Ω

Current input

Current range

0 to 20 mA ± 5%

Input impedance

500

Ω

Resolution

10 bits

Sampling

6 ms

Logic input (if connected to the +24V)

Thresholds

"0": < 5 V – "1": > 10 V

Voltage range

0 to +24 V

Load

95 k

Ω

Input threshold

7.5 V

3

3

0V

Logic circuit common 0V

4

4

ADI2

Analogue or logic
input 2

Assignment in standard
configuration: Motor PTC input

Voltage input

Full scale voltage

10 V ± 2%

Input impedance

95 k

Ω

Current input

Current range

0 to 20 mA ± 5%

Input impedance

500

Ω

Resolution

10 bits

Sampling

6 ms

Logic input (if connected to the +24V)

Thresholds

"0": < 5 V – "1": > 10 V

Voltage range

0 to +24 V

Load

95 k

Ω

Input threshold

7.5 V

Input (PTC)

Trip

3300

Ω

Cleared fault threshold

< 1800

Ω

5

NA

0V

Logic circuit common 0V