55

INSTALLATION AND MAINTENANCE

VARMECA 30

Variable speed motor or geared motor

CONNECTIONS

LEROY-SOMER

3776 en - 07.2007 / h

en

3.5.2.2 - 3-phase AC power supply in accordance with safety standard EN954-1 - category 1 with use of safety input

Note:

For single-phase standards, the power supply is connected to terminals L and N.

QS: Fused isolator: QS must be opened before any intervention on the electrical parts of the drive or motor.
AU: Emergency stop button.
Optional braking resistor. Dissipates the active power returned by the motor onto the drive DC bus in the event of a driving
machine.

Using the safety input means the motor can be stopped in freewheel mode without using a line contactor. The drive’s internal
principles are sufficiently safe to perform a stop using the safety input directly (category 1 of EN954-1).

AU

QS

QS

10V
ADI1
0V
ADI2
24V
ADIO3

DI01

DI2
DI3
DI4

+24V
ENA

RL1
RL2

L1
L2
L3

R+

R-

Fi

PE

2

3

4

5

6

1

8

9

10

11

12

7

13

14

Indicator relay

0-10 V/4-20 mA

speed reference

(local options or external ref.)

Local option indication

External fault input

Forward/Stop

Reverse/Stop

Selection of 0-10 V/4-20 mA

speed reference

Motor PTC input

Braking resistor

(optional)

Jumper to be removed if
optional Braking resistor
connected

Mains supply

VARMECA 31/32

QS

10V
ADI1
0V
ADI2
0V
ADIO3

DI01
+24V
DI2
DI3
+24V
DI4
SDI1
SDI2

COM
RL1C
RL10
SD01
SD02

L1
L2
L3

R+

R-

PE

2

3

4

5

6

1

8

9

10

11

12

13

14

7

15

16

17

18

19

AU

QS

Indicator relay

0-10 V/4-20 mA

speed reference

(local options or external ref.)

Local option indication

External fault input

Forward/Stop

Reverse/Stop

Safety contact

Selection of 0-10 V/4-20 mA

speed reference

Motor PTC input

Braking resistor

(optional)

Mains supply

VARMECA 33/34