Varmeca 30, Variable speed motor or geared motor – Watson-Marlow Varmeca 30 User Manual
Page 10

44
INSTALLATION AND MAINTENANCE
VARMECA 30
Variable speed motor or geared motor
GENERAL INFORMATION
LEROY-SOMER
3776 en - 07.2007 / h
1.5.2 - Standards (Emission)
The maximum emission level is set by the generic industrial (EN 50081-2) and residential (EN 50081-1) standards.
VARMECA 30 conforms to the following standards:
EN 50081-2, EN 61000-6-4 - EN 61800-3, IEC 61800-3.
The second environment includes industrial networks supplied with low voltage but which do not serve buildings
for domestic use. Operation of a drive without an EMC filter in this type of environment may result in interference
on certain electronic appliances located near the drive whose immunity level might not be compatible with industrial
conditions. If it proves impossible to filter the disturbed element, add an external EMC filter.
Emission
Standard
Description
Application
Conformity conditions according to the
switching frequency
With EMC filter
Internal
External
EN 61800-3
Variable speed drive standards
Second environment with
unrestricted distribution (DENR)
VMA 31/32
≤
10kHz
VMA 33/34
≤
11kHz
VMA 31/32
≤
10kHz
VMA 33/34
≤
11kHz
Second environment with
restricted distribution (DER)
VMA 31/32
≤
10kHz
VMA 33/34
≤
11kHz
VMA 31/32
≤
10kHz
VMA 33/34
≤
11kHz
First environment with
unrestricted distribution (R)
-
VMA 31/32
≤
4kHz
VMA 33/34
≤
4,5kHz
First environment with restricted
distribution (I)
VMA 31/32
≤
4kHz
VMA 33/34
≤
4,5kHz
VMA 31/32
≤
10kHz
VMA 33/34
≤
11kHz
EN 50081-1
Generic emission standards for
residential, commercial and light
industrial environments
A.C. supply
-
VMA 31/32
≤
4kHz
VMA 33/34
≤
11kHz
EN61000-6-3
EN 50081-2
Generic emission standards for
the industrial environment
A.C. supply
VMA 31
≤
8kHz
VMA 32
≤
4kHz
VMA 33/34
≤
4,5kHz
VMA 31/32
≤
10kHz
VMA 33/34
≤
11kHz
EN 61000-6-4