beautypg.com

11 supply voltages – Watson-Marlow 520Du User Manual

Page 73

background image

Watson-Marlow 520DuN IP66/NEMA 4X User Manual

73

22.11 Supply voltages

In the table below, “Max load” is the maximum total load on each supply irrespec-
tive of the number of connections.

Note: All DC supplies are stabilised except the +22.5V.

DC
Voltage

Max
load

Lower
D

Upper
D

Typical use

+5V

10mA

9, 19,
23

18, 19

Voltage supply for inputs using
remote switch.
Possible voltage supply for outputs if
only 5V is required.
Pin 9 is specifically used for
footswitch / handswitch operation

+12V

10mA

25

21

Possible voltage supply for inputs using
remote switch.
Possible voltage supply for outputs.
Voltage supply for Watson-Marlow Tube
Monitor leak detector.
Part voltage supply (-12V also needed)
for the Watson-Marlow proximity switch.

-12V

10mA

24

Part voltage supply (+12V also needed)
for the Watson-Marlow proximity switch.

+22.5V

20

Voltage supply for the 520N wash-
down module. Do not use.

+10V

21

Reference voltage for remote poten-
tiometer speed control. Do not use
as a general supply voltage.

This manual is related to the following products: