W A N s u i t e 5 1 6 5

Parity

Sets the parity bit.

Values: None, Odd, Even
Default: None

Stop Bit

Selects the number of bits required to end the character.

Values: 1, 2
Default: 1

Current Pin Status

Shows the status of the DTE Supervisory port pins.

DTR Alarm Control and Status Table

In addition to the configurable fields, the Supervisory screen displays a table
that lets you set the Data Terminal Ready (DTR) Alarm Control parameters
and view the current DTR Alarm Status.

Choices for DTR Alarm Control are “Enable” and “Disable”; the default
setting is “Disable.” Setting DTR Alarm Control to “Enable” allows the unit
to go into alarm on a loss of DTR, which occurs when the Serial port detects
that the DTR signal is low. The DTR Status field indicates the current state of
the DTR alarm.

Services Screen

The Services screen (Figure 3.15) displays the unit’s defined services and the
Interface, Type, and Pair, and Status parameters for each service.

Figure 3.15

Services Screen

The Status for a particular service will display as one of the following:

Dead

The service is not functional because required resources are not

available.

Changed

The service parameter was changed and a Save and Restart is

required for the service to function.

Down

The service is not able to pass data because the physical layer is

down.

Physical Up

The service is not able to pass data because it has not

completed any required negotiations.