Dsx1configtable – Verilink PRISM 3101 (34-00212) Product Manual User Manual
Page 42

SNMP Agent C-2
PRISM 3101/3102
19200 - returned for the SLIP Interface at 19200 baud
38400 - returned for the SLIP Interface at 38400 baud
56000 - returned for the SLIP Interface at 56000 baud
10000000 - returned for the NIC (if Ethernet)
4000000 - returned for the NIC (if Token Ring @ 4 Mb/s)
16000000 - returned for the NIC (if Token Ring @ 16
Mb/s)
1544000 - returned for the DS1 interface. For Port 1 and
Port 2 the rate of the interface is returned, (Number of
Channels * Port Rate Multiplier)
DBU - returns 19200 Async rate used for modem initial-
ization and call setup
ifPhysAddress: (read-only)
GET: returns a value of 0 for all interfaces except the NIC inter-
face, which returns the physical address of the unit
ifAdminStatus: (read-write)
GET: up(1) - returned for all interfaces
SET: not allowed
ifOperStatus: (read-only)
GET: up(1) - returned if the interface is active, and does not
have a testing status
down(2) - returned if the interface is not enabled
testing(3) - returned for the DS1 interface, Port 1, or Port
2 if the interface has a test loop or BERT active.
ifLastChange: (read-only)
GET: returns the time in hundredths of a second since the inter-
face was changed, or reset
RFC 1406 - DS1/E1 MIB
This RFC was published in January 1993, and is meant to
be a replacement for RFC 1232. RFC 1406 is used to man-
age DS1 interfaces, and in our case specifically a T1 inter-
face. The following is a list of the objects contained within
this RFC, and the manner in which the unit responds to
each.
dsx1ConfigTable
dsx1LineIndex: (read-only)
GET: (2) - if a NIC is not installed
(3) - if a NIC is installed
dsx1IfIndex: (read-only)
GET: (2) - if a NIC is not installed
(3) - if a NIC is installed
dsx1LineType: (read-write)
GET: dsx1ESF(2) - the Network Framing is set to ESF
dsx1D4(3) - the Network Framing is set to D4
SET: dsx1ESF(2) - sets the Network Framing to ESF
dsx1D4(3) - sets the Network Framing to D4
dsx1LineCoding: (read-write)
GET: dsx1B8ZS(2) - the Network Coding is set to B8ZS
dsx1AMI(5) - the Network Coding is set to AMI
SET: dsx1B8ZS(2) - sets the Network Coding to B8ZS
dsx1AMI(5) - sets the Network Coding to AMI
dsx1SendCode: (read-write)
GET: dsx1SendNoCode(1) - the unit is not in a Bert Test and
not sending a PLB or LLB loopup/loopdown request to
the Far End
dsx1SendLineCode(2) - the unit is transmitting an
inband LLB loopup signal. Since this occurs for less than
6 seconds, this response probably won’t be seen.
dsx1SendPayloadCode(3) - the unit is sending an out-of-
band PLB loopup request to the Far End, but since this
happens in a fraction of a second, this response will prob-
ably never be seen
dsx1SendResetCode(4) - the unit is sending either an
inband LLB loopdown signal, or an out-of-band PLB
loopdown request, but since these happen so quickly, this
response will probably never be seen
dsx1SendQRS(5) - the unit is in a Network Bert Test
transmitting QRSS pattern
dsx1Send511Pattern(6) - the unit is in a Network Bert
Test transmitting 511 pattern
dsx1Send3in24Pattern(7) - the unit is in a Network Bert
Test transmitting 3:24 pattern
dsx1SendOtherTestPattern(8) - the unit is in a Network
Bert Test and is transmitting a pattern other than QRSS,
511, or 3:24.
SET: dsx1SendNoCode(1) - stops any Bert Tests on the unit
dsx1SendLineCode(2) - the unit will transmit an inband
LLB loopup signal
dsx1SendPayloadCode(3) - the unit will send an out-of-
band PLB loopup request to the Far End
dsx1SendResetCode(4) - the unit will send either an
inband LLB loopdown signal, or an out-of-band PLB
loopdown request, depending on what the Far End has
active
dsx1SendQRS(5) - the unit will start a Network Bert Test
transmitting QRSS pattern
dsx1Send511Pattern(6) - the unit will start a Network
Bert Test transmitting 511 pattern
dsx1Send3in24Pattern(7) - the unit will start a Network
Bert Test transmitting 3:24 pattern
dsx1SendOtherTestPattern(8) - the unit will start a Net-
work Bert Test, running a Clear test
dsx1CircuitIdentifier: (read-write)
GET: Returns the value of the Circuit Identifier for the unit, this
defaults to ‘TxPORT Prism 3100’
SET:Sets the Circuit Identifier of the unit to the specified string
dsx1LoopbackConfig: (read-write)
GET: dsx1NoLoop(1) - the unit does not have any loops active
dsx1PayloadLoop(2) - the unit has a PLB active
dsx1LineLoop(3) - the unit has a LLB active
dsx1OtherLoop(4) - the unit has a Port Loop active