Alarms screen -4, Alarms screen – Verilink PRISM 3101 (34-00212) Product Manual User Manual
Page 20

Configuration 3-4
PRISM 3101/3102
Alarms Screen
The Alarms screen (Figure 3-7) allows you to view the cur-
rent alarm status of the network and the DTE lines.
NETAlarms: These status lines display the selected ele-
ment’s current network signal alarm state (Table 3-G).
Alarms are determined by the selectable thresholds in
Alarm Configuration on page 3-11.
DTEAlarms: These status lines display the selected ele-
ment’s current DTE signal alarm state (Table 3-H). Alarms
are determined by the selectable thresholds in
Alarm Configuration on page 3-11.
Selectable thresholds in the Alarm Parameters screen and
the DTR Alarm may be enabled or disabled for the ports in
the Port Parameters screen.
(alarm status): The main body of the Alarms screen shows
the current count for parameters that may be used to trigger
an alarm.
The Current column displays a total of the preceding 15
one-minute intervals. At the end of each one-minute inter-
val, the oldest minute of the 15-minute interval is discarded.
The Threshold column displays the values set in the Alarm
Configuration screen (page 3-11). Parameters having a cur-
rent value equal to or greater than its non-zero threshold
generates an alarm. Any parameter with a threshold value of
zero is disabled from generating alarms.
The parameters shown on the Alarms screen are
updated at approximately five second intervals.
Power Loss Seconds: This field displays the number of
seconds that the element has been without power since this
value was last cleared.
Table 3-G NET Alarm Indicators
Alarm
Description
-------
No status is available
OK
No alarm threshold has been exceeded, although
errors may exist which do not exceed thresholds.
ERRS
The Errored Seconds, Severely Errored Seconds, or
Bipolar Errored Seconds threshold is exceeded.
LOSS
The Loss Of Signal Seconds threshold is exceeded.
OOFS
The Out Of Frame Seconds threshold is exceeded.
RAIS
The Remote Alarm Seconds threshold is exceeded.
AISS
The Alarm Indication Seconds threshold is
exceeded.
UAS
The Unavailable Seconds threshold is exceeded.
DBA
Dial Backup Active
DBF
Dial Backup Failed
PORT 1
DTR Alarm on PORT 1
PORT 2
DTR Alarm on PORT 2
Figure 3 -7 Alarms Screen
Table 3-H DTE Alarm Indicators
Alarm
Description
OK
No alarm threshold has been exceeded, although
errors may exist which do not exceed thresholds.
OOFS
The Out Of Frame Seconds threshold is exceeded.
PORT 1
DTR Alarm on PORT 1
PORT 2
DTR Alarm on PORT 2