Verilink PRISM 3002 (34-00277) Product Manual User Manual
Page 50

A-2
F
LASH
PROM D
OWNLOAD
P
ROCEDURE
7
Select the baud rate for
configuring the
communication program. The
valid choices for the 3002 are
19200, 38400, and 57600 (see
Upgrading Software on page
3-3).
8
The TEST and LOOP buttons only control the SUPV port rate for downloading
software for the unit’s Flash PROM. Setting the SUPV port rate for terminal
operation is done by hardware (see SUPV Port Bit Rate on page 3 -2).
9
Enter the hex file to be downloaded. When the Device Type was selected, the
program automatically performed a look-up for existing applicable hex files in the
local directory. If a file is found, it is displayed in this field. This filename can be
accepted or another may be entered.
10
Connect the PC serial COM port to the SUPV port of the 3002 with a DB-25 to
6-pin modular cable assembly (P/N 9 -1001-028-2). If the COM port has nine
pins, use a 9-pin to 6-pin modular cable assembly (P/N 9 -1001-025-2).
11
In Switched mode (step 5 above), press the 3002 front panel TEST and LOOP
buttons to match the rate selected in step 7. Power restart the unit with the buttons
pressed.
12
From the FLASH Loader screen, select the Help option and follow the instructions
for configuring the baud rate. This operation is different for each device type so
read the instructions carefully. If the baud rate cannot be successfully configured,
contact Verilink Technical Support.
13
The Utilities option is used for saving and restoring the configuration parameters
for the 8100A Site Controller.
Table A-1 Flash PROM Download Rate
Botton
19.2 kbps
38.4 kbps
57.6 kbps
TEST
Press
Press
LOOP
Press
Press
TxPORT FLASH Loader
Time: HH:MM:SS
Date: MM/DD/YY
Rev: X.X
Device Type:
[Generic]
Download Method: [Switched]
ComPort
[Com1]
Baud Rate:
[19200]
Hex Filename:
[0026-214.hex]
Help
Utilities
Download
Exit
MESSAGES
Figure A-1 TxPORT FLASH Loader Screen