Nms address, Supv port bit rate, Nms address -2 supv port bit rate -2 – Verilink PRISM 3002 (34-00277) Product Manual User Manual
Page 20: Nms address a

3-2
H
ARDWARE
C
ONFIGURATION
AND
T
ESTING
NMS Address
Switches S1-1 through S1-8 set the NMS address. When using the 3002 with an
8100A Site Controller, each element must have a unique unit address. The 8100A
Site Controller can address up to 100 units (with addresses from 1 to 100). If the
unit is not connected to a site controller, the NMS unit address should remain at
the factory default setting of 1 where Position 1 is Left and all other positions are
Right.
Switch positions S1-1 through S1-8 are used to create an 8-bit binary code for an
address in the range of 1 to 253. Switch position S1-1 is the least significant bit
(LSB) and S1-8 is the most significant bit (MSB). If a switch is Right, its value is
0. If Left, its value is that shown on the left. The values are additive. For example,
to set a unit address to 5, position S1 -3 (value is 4) and position S1-1 (value is 1)
would be set Left for a unit address of 5 (4+1). All other positions would be set
Right. If all the switches are Right, the address is 1.
SUPV Port
Bit Rate
Switch S1-9 and S1 -10 set the supervisory port bit rate. This is a serial RS-232
DCE port configured for 8 bits, no parity, and 1 stop bit. Table 3 -A shows the
available speeds.
Left
Right
Figure 3-2 Switch S1
12
3
4
5
6
7
8
91
0
SUPV Rate
SUPV Rate
128
64
32
16
8
4
2
1
LSB
MSB
Bin
a
ry
v
alu
es
0
0
0
0
0
0
0
0
Table 3-A SUPV Port Bit Rate
S1-9
S1-10
SUPV Port Rate
Left
Left
1.2 kbps
Right
Left
2.4 kbps
Right
Right
9.6 kbps
Left
Right
19.2 kbps