Start test, Reset errors, Linefaultand loopstatus – Verilink PRISM 3002 (34-00277) Product Manual User Manual
Page 36: Net status, Near loops, Far loops, Configuration screens, Net status -14, Near loops -14 far loops -14, Configuration screens -14

4-14
T
ERMINAL
C
ONFIGURATION
AND
T
ESTING
% EFS
This ratio is derived from the number of error-free seconds divided by the number
of seconds accumulated in Elapsed Time.
Start
Test
Pressing Enter with the cursor on this field starts the selected test pattern. Test In
Progress appears once the test has started. To end the test, press Enter on Stop
Test.
Reset
Errors
Pressing Enter with the cursor on this field causes the test error results to be
cleared to zero.
The following fields are for display only. They reflect the selected test parameters
and the results of these tests only:
Line Fault and
Loop Status
NET Status
This field displays the fault status of the network. It indicates current fault
conditions. It does not indicate that alarm thresholds are exceeded. Status
indications are described in Table 4-4.
Near Loops
Displays the loop status of the near element.
Far Loops
Displays the loop status of the far element.
Configuration
Screens
The Configuration screens allow viewing and setting configuration parameters for
the network elements.
To send a new configuration to the unit, press Enter on one of the fields or exit the screen.
The underlined values are the factory default parameters.
Table 4-4 Status Indications
Status
Description
-------
No status is available
OK
No errors are currently detected.
ERR
Frame bit errors, CRC errors, or BPVs are detected.
LOS
A loss of signal condition exists.
OOF
An out of frame condition exists.
RAI
Far end is receiving a remote alarm indication signal.
AIS
The far end is receiving an alarm indication signal.
UAS
An unavailable signal state exists due to consecutive
severely errored seconds.