Alarmsscreen, Net alarms, Alarms screen -5 – Verilink PRISM 3002 (34-00277) Product Manual User Manual
Page 27: Net alarms -5, Alarms screen

Alarms Screen
4-5
Alarms Screen
The Alarms screen (Figure 4-4) allows viewing the current alarm status of the
network and the DTE lines.
NET Alarms
These status lines display the selected element’s current network signal alarm state
(Table 4-2). Alarms are determined by the selectable thresholds in the Alarm
Configuration screen (see Figure 4-8 on page 4-17).
Figure 4-4 Alarms Screen
3002 DSU 1.00/2.40 3 0 0 2 Date: 06/24/97
No Far End Response Time: 08:36:09
------------------------------------ ALARMS ------------------------------------
Element: NEAR]
NET Alarms: NONE
DTE Alarms: NONE
Current Threshold
Loss of Signal Seconds (LOSS): 0 5
Errored Seconds (ES): 0 45
Severely Errored Seconds (SES): 0 5
Unavailable Seconds (UAS): 0 0
Out of Frame Seconds (OOFS): 0 5
Remote Alarm Seconds (RAS): 0 0
AIS Seconds (AISS): 0 0
BPV Seconds (BPVS): 0 0
Power Loss Seconds (PLS): 0
Reset Alarm Registers: (RESET)
----------------------------------- Messages -----------------------------------
Local Screen
Table 4-2 NET Alarm Indicators
Alarm
Description
-------
No status is available.
OK
No alarm threshold has been exceeded, although errors
may exist which do not exceed thresholds.
ERRS
The Errored Seconds, Severely Errored Seconds, or
Bipolar Errored Seconds threshold is exceeded.
LOSS
The Loss Of Signal Seconds threshold is exceeded.
OOFS
The Out Of Frame Seconds threshold is exceeded.
RAIS
The Remote Alarm Seconds threshold is exceeded.
AISS
The Alarm Indication Seconds threshold is exceeded.
UAS
The Unavailable Seconds threshold is exceeded.
DBA
Dial Backup Active.
DBF
Dial Backup Failed.