Terminal configuration and testing, Interface start-up, 4 terminal configuration – Verilink PRISM 3002 (34-00277) Product Manual User Manual
Page 23: And testing, Interface start-up -1, 4, terminal configuration and testing, Erminal, Onfiguration, Esting

4
T
ERMINAL
C
ONFIGURATION
AND
T
ESTING
The terminal interface is an embedded firmware application program. This
information can be accessed through the SUPV port (see Supervisory (SUPV) Port
on page 2 -3).
It requires an ANSI-compatible VT100 terminal (ASCII), or a computer running
an ANSI terminal-emulation program. The terminal interface uses ASCII break
and escape commands, which are implemented differently with the various
terminal emulation programs.
Interface
Start-up
Once a compatible terminal is properly connected to the unit, a terminal interface
session can be started by sending a break command to the unit (or by pressing
Enter four times). The Main Menu screen. (Figure 4-1) is displayed if a password
has not been specified.
If a password has been previously established, the correct password must be
entered to continue the session.
The password is case-sensitive.
3002 DSU 1.00/2.40 3 0 0 2 Date: 06/24/97
3002 DSU 1.00/2.10 Time: 08:35:47
------------------------------------- MAIN -------------------------------------
Element: [NEAR]
Alarms
Performance
Maintenance
Configuration
Utilities
----------------------------------- Messages -----------------------------------
Local Screen
Figure 4-1 Main Menu Screen