Configuration 3-1

1061 Multicast Card

3. Configuration

The 1061 T1 Multicast can be configured through manual
switch settings (hardware) and/or through a VT100 terminal
connection (software).

All default options in this manual are underlined.

Hardware Configuration

Hardware configuration is set using four toggle switches and
two dual in-line package (DIP) switches. These switches
allow you to configure simple applications. Refer to Figure
3-1 f
or switch locations. A removable configuration guide
(45-00117) is included in the back of this manual.

Address

This 8-pin switch (S1) sets the NMS address of the unit.
Valid addresses are 1 through 252. Address values 253
through 255 are reserved. Zero (or no channel) is the
default.

NMS Bit Rate

S2-1 and 2-2 set the NMS bit rate.

SUPV Bit Rate

S2-3 and S2-4 set the Supervisory port bit rate.

LSB

S2-5 sets the Least Significant Bit with respect to the duplex
select. Refer to Table 3-D for setting information.

Duplex Select

S2-6 and S2-7 select the channel (1-12) that is full duplexed
to the selected (A or B) input channel. No channel is
selected on zero. Table 3-D displays the switch settings for
the duplex select. The expansion settings (A EXPD, B
EXPD, and A/B EXPD) full duplex back to their respective

Table 3-B NMS Bit Rate

kbps

S2-1

S2-2

19.2 B

B

9.6

A

A

2.4

B

A

1.2

A

B

Table 3-C SUPV Bit Rate

kbps

S2-3

S2-4

19.2

B

B

9.6

A

A

2.4

B

A

1.2

A

B

T1 input lines. For example, the A EXPD setting full
duplexes the return feed back to the T1 A input line; the
B EXPD setting full duplexes the return feed back to
the T1 B input line; and the A/B EXPD setting full
duplexes the return feed back to the respective T1 A
and T1 B input lines.

When you bypass from an input
line to an expansion line, you

must have another 1061 unit connected
to the expand line. Failure to have a con-
nection will cause the signal to be inter-
rupted.

Figure 3-1 1061 Front Panel