2-2 Installation

1061 Multicast Card

T1 Multicast Port

The 50-pin female connector is used for the expanded out-
puts of either the A or B inputs per ANSI.T1 403-1988.

Alarm/Power

The Alarm/Power is a ten-pin connector used for supplying
power and providing alarm connections.

Alarm

The alarm connection operates in a normally closed mode
(NC - opens on alarm) on pins 6 and 9 or in a normally open
mode (NO - closes on alarm) on pins 6 and 10. The contacts
are rated at 1.0 amp AC or 1.0 amp DC over 18- to 20-
gauge wire (recommended).

External Alarm

These unpowered, isolated inputs indicate external alarms
on inputs A and B. External alarm A is connected on pin 1
(+) and pin 2 (-). External alarm B is connected on pin 3 (+)
and pin 4 (-). They are 10 mA current loops and must be
powered externally.

Power

The power connection requires a -48 VDC power source
capable of supplying 50 mA current. It supplies current to
the 1061 cards and generates a circuit alarm. The -48 VDC
lead is connected to pin 7 with the return lead connected to
pin 5. The chassis ground lead is connected to pin 8. When
connecting these pins, 18- to 20-gauge wire is recom-
mended.

Network Management

An NMS bus in the 1061 allows for network management
from an 8000 Element Manager or an 8100A Site Controller
as a remote or far end element via the SUPV port.

Table 2-D T1 Multicast Port Pinout

Tip

Ring Function Tip

Ring

Function

1

26

Output # 1

13

38

Output # 7

2

27

Input #1

14

39

Input # 7

3

28

Output # 2

15

40

Output # 8

4

29

Input # 2

16

41

Input # 8

5

30

Output # 3

17

42

Output # 9

6

31

Input # 3

18

43

Input # 9

7

32

Output # 4

19

44

Output # 10

8

33

Input # 4

20

45

Input # 10

9

34

Output #5

21

46

Output # 11

10

35

Input # 5

22

47

Input # 11

11

36

Output # 6

23

48

Output # 12

12

37

Input # 6

24

49

Input # 12

25

50

Frame Gnd

Table 2-E Alarm / Power Pinout

Pin

Function

1

External Alarm A (+)

2

External Alarm A (-)

3

External Alarm B (+)

4

External Alarm B (-)

5

48 VDC Return

6

Alarm Common

7

-48 VDC

8

Frame Ground

9

Normally Closed

10

Normally Open