Operation – Tri Tool 576AC Sever Machine with Air Motor User Manual
Page 10

92-1176 : Orig. 041012
TRI TOOL INC.
1 0
IN GENERAL:
Read the operating instructions carefully before attempting to operate the
Model 576AC SEVERMASTER™.
Inserting the collet:
Select the desired size collet for the pipe or tube to be worked on.
Raise the handle to release pressure on the adjust nut.
Rotate the adjust nut until the eyebolt can be raised out of the slot and
then the hinge bracket may be rotated back and down.
Remove the pusher sleeve from the main housing.
Remove the collet, if there is one, from the inside of the main housing.
Insert the correct collet into the main housing and then slide the pusher
sleeve back into the main housing and into contact with the collet.
Rotate the hinge bracket back up and let the eyebolt drop back into the
slot.
Rotate the adjust nut on the eyebolt to secure in the slot.
Mounting the tool holder:
Select the tool holder which will allow the tool bit to reach the work
surface.
Place the tool holder in the tool holder slot.
Insert the (4) four cap screws that hold the tool holder in place.
Graduation Marks
Feed rate Lock Screw
Feed rate Adjustment Screw
Feed Arm