beautypg.com

Tri Tool 224B Single Point User Manual

Page 21

background image

21

92-0833 : Orig. 990603

Model 224B Single Point

Problem:

There is a loss of hydraulic power.

The hydraulic supply pressure is too low.
The hydraulic filter is plugged.
The hydraulic line size is insufficient.
The hydraulic line is too long.

Problem:

The tool bit will not reach the work.

Incorrect tool blocks are installed for the size of the pipe or tube
being worked on incorrect tool bit is installed.

Problem:

The air motor will not start.
The air power supply is shut off.
The air motor is damaged and will not run free. The air motor needs
lubrication.
Add lubrication and do not run the air motor for a few minutes, then
try running the motor. Tap on the side of the air motor casing lightly
with a piece of wood or with a soft rubber mallet just in case the vanes

may be sticking.
Sand or other foreign material may be in the vanes of the air motor.

Problem:

The hydraulic motor will not start.
The hydraulic power supply is shut off.
The hydraulic motor is damaged and will not run free.