100 bus control – Tascam MMR-8 User Manual
Page 100

TASCAM MMR-8 Owner’s Manual • Chapter 6 • File Format Support
100
100 Bus Control
100 Sync Group
Sets the MMR Bus sync group assignment for the MM series unit. Default is 1.
110 MMR Bus Request
Sets the status request for the MM series unit on the MMR Bus.
§ Off
The MM unit will not be active on the MMR Bus (default).
§ Slave
The MM unit will request to be a Slave on the MMR Bus.
§ Master
The MM Unit will request to be the Master on the MMR Bus.
111 Ident Request
Sets the unit ID (Ident) request for the MM series unit on a particular MMR Bus sync group. This value
can be any number between 00 and 99, or can be set to Auto. When Auto request is on, the system will
assign ID numbers based on when units become active on the bus and their unique serial numbers. The
recommended practice is to assign units to unique individual ID numbers and to avoid using the Auto
setting. If a conflict arises, the system will automatically resolve it and will not allow duplicate ID
numbers. Default is auto assign.
112 Ident Assigned
This setting shows the Ident assigned for the MM series unit on the MMR Bus. Since there can be no
duplicate ID numbers on the MMR Bus Sync Group, it is possible that some units will be assigned a
status other than that requested.
120 Lynx Bus
Sets the MM series unit’s status on the TimeLine Lynx bus.
§ Off
The MM unit will not be active on the Lynx Bus (default).
§ Slave
The MM unit will request to be a Slave on the Lynx Bus.
§ Master
The MM Unit will request to be the Master on the Lynx Bus.
121 Lynx Bus Address
Sets the Lynx bus address for the selected MM series machine. The default is 1.
122 Lynx Bus V500 Mode
Sets the MM series machine to work with TimeLine Lynx V500 software. The default value is off.