TE Technology TC-36-25-RS485 User Manual
Page 17
17
d) See the “Controller Wiring Diagram (Single Power Supply Setup)” for further details.
1.4.2 Two Power Supplies Operation:
Make sure the power supplies are NOT energized while making electrical connections to the controller.
a) Remove jumper across JP6‐1 and JP6‐2
b) Connect the constant DC voltage controller power supply (12 to 36) VDC, 200 mA minimum to the controller:
Positive power supply terminal to JP6‐2
Negative power supply terminal to JP6‐3
Note: JP6 is a Molex connector, part number 22‐23‐2031
c) Connect the constant DC voltage TE device power supply (0 to 36) VDC to the controller:
Positive power supply terminal to WP3
Negative power supply terminal to WP4
Install a 1.5 k, 1 W (customer‐supplied) resistor across the positive and negative power‐supply
terminals.
d) Do NOT connect the TE device to the controller at this time.
e) See the “Controller Wiring Diagram (Two Power Supplies Setup)” for further details.
1.5
Turn power on to both the computer and the power supply(s) (which in turn powers up the controller) and to the
RS485 converter, if applicable. The on‐board green LED will flash at a steady rate to indicate that the controller is
energized correctly.
Do not mount the controller to a surface which is exposed to a source of heat, such as from electronics,
machinery, or solar radiation.
Do not cover the controller with any object or otherwise restrict natural convection airflow around the
controller. Doing so could cause the controller to overheat.
Do not mount the controller to an insulating surface. Doing so could cause the controller to overheat.
Do not operate the controller in such a manner as to cause the surface temperature of the circuit board
or its frame to reach 70 °C. Otherwise the controller might be damaged and there might be a risk of fire as
a result.
Do not allow the controller to be exposed to water (such as from dripping or leaking water lines or from
water‐vapor condensation if the surface temperature of the controller is below the dew point
temperature).
Do not allow metallic dust/shavings to contact the controller electronics.
1.6
TE Technology offers the optional RS485 Adapter from our website (pictured below). It includes a pre‐configured
USB‐COMi adapter, device drivers on a CD disk, USB cable, and a pre‐wired 9‐pin D‐sub connector to connect the
adapter to the temperature controller. If you are using the RS485 Adapter supplied by TE Technology, you can
simply install the device drivers and connect the adapter to the computer and to the temperature controller (See
RS‐485 Communications Connections diagram).