Miscellaneous – Start pattern generator.
27…0
Not used.
There is nothing to pass on to the Control Register in this mode; it is only triggering
the pattern generator, which then starts read back from the memory ‘Burst Size’
(current value of the register) data samples starting from the current ‘Start Address’
and sends them to all the DACs at the same time. This operation is repeated until a
‘Stop pattern generator’ control word is received.
It is to the used not to send any other control word while the pattern generator is
being running.
Miscellaneous – Stop pattern generator.
27…0
Not used.
There is no parameter to pass on to the Control Register in this mode.
Miscellaneous – Internal Register Reset.
27…0
Not used.
There is no parameter for this command; it resets all internal registers.