beautypg.com

Studio Technologies 50 2004 User Manual

Page 42

background image

Issue 6, September 2004

Model 50/51 User Guide

Page 42

Studio Technologies, Inc.

Function: Control Room Level

Byte Value Description
1 F0H

System-Exclusive

Message

2

00H

1st Byte of Studio Tech ID

3

00H

2nd Byte of Studio Tech ID

4

56H

3rd Byte of Studio Tech ID

5

01H

Product ID (Model 50)

6

07H

Function: Control Room Level

7

0nH

Level, MSB, range 0-3, see note 1

8

nnH

Level, LSB, range 00-7F, see note 1

9

F7H

EOX, End of System Exclusive

Note 1: MSB=0 allows LSB to control lower 128 level steps, MSB=1 allows LSB field to control upper
128 level steps. (In operation MSB=0/LSB=00 gives full mute, MSB=1/LSB=7F gives maximum output
level.)
MSB=2 places function in reduced precision mode, where LSB=00 is full mute, LSB=7F is maximum
output.
MSB=3 places function in reduced precision, reverse range mode, where LSB=7F is full mute, LSB=00
is maximum output.

Function: Studio Level

Byte Value Description
1 F0H

System-Exclusive

Message

2

00H

1st Byte of Studio Tech ID

3

00H

2nd Byte of Studio Tech ID

4

56H

3rd Byte of Studio Tech ID

5

01H

Product ID (Model 50)

6

08H

Function: Studio Level

7

0nH

Level, MSB, range 0-3, see note 1

8

nnH

Level, LSB, range 00-7F, see note 1

9

F7H

EOX, End of System Exclusive

Note 1: MSB=0 allows LSB to control lower 128 level steps, MSB=1 allows LSB field to control upper
128 level steps. (In operation MSB=0/LSB=00 gives full mute, MSB=1/LSB=7F gives maximum output
level.)
MSB=2 places function in reduced precision mode, where LSB=00 is full mute, LSB=7F is maximum
output.
MSB=3 places function in reduced precision, reverse range mode, where LSB=7F is full mute, LSB=00
is maximum output.

This manual is related to the following products: