Model 46A User Guide

Issue 1, September 2014

Studio Technologies, Inc.

Page 17

switch is in its on (up) position the nominal

level is –10 dBu. This setting is appropri-

ate when beltpacks from RTS, such as the

BP325, or listen-only talent amplifier units

from Studio Technologies, Inc. are con-

nected. For best Model 46A performance

it’s important that the 2-wire nominal level

selection be made correctly.

4-Wire Nominal Audio Level
DIP switches 3 and 4 are used to configure

the nominal level of the input and output

circuitry associated with interface 1’s two

4-wire input and output connections. Four

level settings are available: 0, +4, +6, and

+8 dBu. Prior to setting these DIP switches

it’s important to determine the nominal au-

dio level of the equipment connected to the

Model 46A’s 4-wire input and outputs. This

may take a little investigation but is impor-

tant for obtaining the best possible Model

46A performance.
The 0 dBu setting is provided specifically

for use when a Model 46A is intercon-

nected with a Clear-Com matrix intercom

system. The +4 dBu setting is appropriate

when standard audio lines with “+4” nomi-

nal levels are interconnected. The +6 dBu

setting can be appropriate when intercon-

necting with equipment manufactured in

Europe, such as the digital matrix intercom

systems from Riedel. The +8 dBu setting is

provided specifically when interconnecting

the Model 46A with audio signals associ-

ated with an RTS ADAM-Series of matrix

intercom system. This includes the related

RVON-I/O unit.
When DIP switches 3 and 4 are in their off

(down) position the nominal level is set for

0 dBu. When switch 3 is on (up) and switch

4 is off (down) the nominal level is +4 dBu.

When switch 3 is off (down) and switch 4 is

on (up) the nominal level is +6 dBu. When

both switches 3 and 4 are in their on (up)

position the nominal level is configured for

+8 dBu.

Advanced

Configuration

Four DIP switches are provided on the

Model 46A’s back panel. They allow the

two interfaces to be configured for sev-

eral advanced operating modes. Refer to

Figure 6 for a detailed view of these DIP

switches. The available configurations

include auto terminate, auto null button

operation, and factory test.

Figure 6. Detail of back panel showing the

Advanced Mode DIP switches

Auto Terminate

The auto terminate function is designed to

ensure that each 2-wire-to-4-wire interface

circuit remains stable under most oper-

ating conditions. Specifically, 200 ohm

impedances are automatically applied to

both pins 2 and 3 of a Model 46A 2-wire

party-line interface when that interface is

configured for external power and no ex-

ternal source of intercom power is detect-

ed on pins 2 or 3. This function is directly

compatible with RTS TW-Series intercom