beautypg.com

Ac mains power – Studio Technologies 46A User Manual

Page 15

background image

Model 46A User Guide

Issue 1, September 2014

Studio Technologies, Inc.

Page 15

has current flowing through it for a mini-

mum of 30 milliseconds. A special case

arises when the auto null button operating

mode has been set to independent. This

requires one front-panel button tap to auto

null channel 1 and two button taps to auto

null channel 2. The remote control equiva-

lent for one tap is current flowing for a mini-

mum of 30 milliseconds. The equivalent for

two taps is current that flows for 30 millisec-

onds, then a minimum no-current period of

30 milliseconds, followed by current flow for

a minimum of 30 milliseconds. The second

period of current flow must come within one

second of the start of the first.
Once the interconnect method and the

source of the control signals have been

selected, refer to Figure 4 for connection

details. Ensure that the connected signals

follow the specified polarity or damage to

the opto-coupled inputs may occur.
It’s important that a competent technician

be available to perform the actual remote

control input connection process. As ex-

pected, mating the interconnecting cable

assembly with the Model 46A’s 10-pin

“header” requires removing the unit’s cover.

As such, this must be done only after con-

firming that all sources of mains power have

been disconnected from the unit.

AC Mains Power

The Model 46A operates directly from AC

mains power of 100 to 240 V, 50/60 Hz. As

a “universal mains input” device, there are

no switches to set or jumpers to install. A

3-pin IEC 320 C14 inlet connector on the

Model 46A mates with a detachable mains

cord set. For units shipped to North Amer-

ica and Japan a cord is supplied that has

a North-American (NEMA 15L) standard

plug on one end and an IEC 320 C13 con-

nector on the other. Units bound for other

destinations require that the appropriate

cord set be obtained. The wire colors in

the mains cord should conform to the

internationally recognized color code and

should be terminated according to the fol-

lowing chart:
Connection

Wire Color

Neutral (N)

Light Blue

Line (L)

Brown

Earth/Ground (E) Green/Yellow

Safety Warning: The Model 46A does

not contain an AC mains disconnect

switch. As such, the AC mains cord

plug serves as the disconnection de-

vice. Safety considerations require that

the plug and associated inlet be easily

accessible to allow rapid disconnec-

tion of AC mains power should it prove

necessary.

As soon as AC mains power is applied

the Model 46A will begin its power-up

sequence. As a “boot up” indication the

power LED and each of the status LEDs

will momentarily light. After the sequence

has completed the power LED will again

light and remain lit. The unit is now fully

functional.


10-Pin

9-Pin D-Sub

Function

Header (P9) Interface Cable

Remote Auto Null Interface 1 +

7

4

Remote Auto Null Interface 1 –

9

5

Remote Auto Null Interface 2 +

2

6

Remote Auto Null Interface 1 –

4

7

Remote “Mic Kill” +

6

8

Remote “Mic Kill” –

8

9

Figure 4. Remote control input pin-out chart