SOMFY SYSTEMS, INC. reserves the
right to update, change or modify
these instructions without prior notice.

REF. NO: 940125A

COPYRIGHT C SOMFY SYSTEMS, INC.

2/03

SOMFY SYSTEMS, INC.

47 Commerce Drive
Cranbury, NJ 08512

SOMFY CANADA

6315 Shawson Drive, Unit #1
Mississauga, Ontario L5T1J2

SOMFY MEXICO S.A. De C.V.

Calle 3 No. 47, Loc. E-5
Fracc Ind. Alce Blanco
Nau., Edo. de Mex C.P. 53370

5) Back to the factory configuration (to

the OREA RTS motor memory using a previously recorded transmitter)

**A.Perform a power cut in the following sequence:

1. Power-off - 2 sec. minimum
2. Power-on - 5 to 15 seconds
3. Power-off - 2 sec. minimum
4. Power-on

The end product moves for 5 seconds in one direction,
to indicate that the double power cut has been recorded.
The motor is in PROGRAMMING STAT for 2 minutes.

reset

E

B. RESTORING FACTORY MODE

Press and

the programming button for more than 7 seconds

of the NEW RTS transmitter. The end-product will jog briefly UP/DOWN
twice. Once after 1 second and again after 7 seconds. This indicates the
OREA RTS motor has been completely cleared.

HOLD

>5 sec.

PREVIOUSLY RECORDED TRANSMITTER

5 seconds

!

WARNING:

This type of power cut affects all

the OREA RTS motors on the same power line. To
avoid resetting of non-concerned motors, press briefly
any button of their assigned transmitter. (UP, STOP, or
DOWN) The non-concerned motors will return to
USER MODE.

**RESETTING MOTORS BACK TO USER MODE

NOTE: A double power cut cannot be achieved if the motor is still in

FACTORY or INSTALLER mode. First program a transmitter into