Installer Mode
This mode allows for
final programming
readjusting of the DOWN limit only and
5
IMPORTANT
If the installation is made up of several OREA RTS motors, only one OREA RTS motor must be powered during programming.
This will avoid interference with the first programming of each OREA RTS motor. If several motors are connected on the same
power supply please
6.5 "Resetting motors back to USER MODE".
refer to the Warning note in Section
The application jogs briefly UP/DOWN indicating that the UP and DOWN position
have been memorized in the motor. The motor is now in
and operates in a momentary fashion
INSTALLER MODE
.
Record the UP and DOWN
positions by pressing the
STOP button for more than
2 seconds. The setting of the
end limits is now completed.
Stop the motor at the desired DOWN limit
> 2 seconds
To set the DOWN limit, press
the STOP and DOWN buttons
for more than 2 seconds. Release
the buttons once the end-product
begins to move, and be prepared
to stop it at its DOWN limit.
> 2 seconds
IMPORTANT!
> 2 seconds
To set the UP limit, press the
STOP and UP buttons for more
than 2 seconds. Release the
buttons once the product begins
to move.
STOP
d
c
The awning goes up and reaches the completely
closed position of the box.
The end-product moves towards the DOWN limit.
*If the INSTALLER MODE directly follows FACTORY MODE, with no power interruption to the motor, go directly to Section 5.2
HELPFUL HINTS:
1. Once the end limits are confirmed during FACTORY MODE, it is possible to delete the limits and start over at the beginning.
- Just press UP & DOWN simultaneously for 2 sec. until the motor jogs. This deletes the limits and starts you at the
beginning of Factory Mode.
2. If the OREA motor is still powered after confirming the limits, only this activated transmitter/channel can be recorded by
pressing the programming button (this prevents other transmitters from being recorded during factory environments).
3. The only way to record a different transmitter/channel is to perform a single power cut in INSTALLER MODE (which is right
after both limits have been confirmed). Then press any transmitter button (UP, STOP or DOWN)
to activate
this transmitter's address into the memory of the motor. The first transmitter you activate will only respond, unless you
perform another single power cut. Then press the programming button to record this new transmitter/channel.
independently
4) Adjust the end product to the up position, approximately 4 inches before the cassette awning is completely closed.
This distance is required for the motor to activate the low torque mode prior to closing and to establish a reference
starting point.
5) Setting of the END LIMITS
Read the complete limit setting procedure before proceeding with setting the UP and DOWN limits.
If necessary, adjust the
correct down position
using the UP and DOWN
buttons. Remember the
motor responds to the
transmitter in a
momentary fashion.
Always start at
the upper
reference point
4 in.
a
b