User mode – SOMFY OREA User Manual
Page 5
Release it after the end-product jogs briefly UP/DOWN
indicating that the OREA RTS motor is in a
PROGRAMMING STATE
Release it after the end-product jogs briefly UP/DOWN
indicating that the transmitter has been
memorized or deleted in the OREA RTS motor
First activate the OREA RTS memory by pressing
the programming button for more than 2 sec. of
the transmitter/channel previously recorded in the
motor's memory.
Now, select the transmitter/channel you wish to
memorize in the OREA RTS motor.
Press briefly on the programming button of the
new transmitter you wish to assign or delete.
2) Add or Delete a transmitter/channel in the memory of OREA RTS motor. The procedure is the same for adding or deleting
a transmitter/channel. If the transmitter/channel has not been previously memorized it will be added instead of deleted.
Transmitter
previously
recorded
New
Transmitter
>2 Seconds
Repeat this procedure for each additional transmitter/channel you wish to add or delete. It is not possible to delete the
transmitter/channel used to enter the programming state.
!
!
USING THE INTERMEDIATE POSITION
Manually
Automatically
: Press the intermediate button (STOP button)
when the motor is not in motion
: When the SOLIRIS RTS sensor reaches the
set DAYLIGHT THRESHOLD, it gives a DOWN command. The
end-product will move to the intermediate position only if the
intermediate position has been programmed. Otherwise
it will move to the DOWN limit.
TO DELETE THE INTERMEDIATE POSITION
Reach the intermediate position. Then press on the STOP
button and hold it (approx. 5 sec.) until the end-product
jogs briefly. The IP has been deleted.
Press the STOP button
for more than 5 seconds
1) Intermediate position (IP)
RECORDING THE INTERMEDIATE POSITION
Adjust the intermediate position by using the UP, DOWN, and STOP
button on your control. The OREA motor must be in stop position
before programming.
Release it after the end-product jogs briefly
UP/DOWN indicating that the intermediate
position has been memorized in the motor
>5 Seconds
User Mode
This mode is for operating the motor by the end user
One Intermediate Position (IP) can be programmed into the OREA RTS. No reference point is necessary due to the
electronic limit switch. The IP can be reached from any point between the end limits.
6
IP