Increase/decrease flow switch, Master switch, Way selectable section switches – Smithco Switch Pro Installation & Operation Manual User Manual
Page 16: Using accuboom override

Chapter 3
12
Switch Pro™ Installation & Reference Manual
Increase/Decrease Flow Switch
For products in automatic control mode, the Increase/Decrease flow switch is used to increase or decrease the 
target rate of products selected and actively displayed on the Envizio Pro or Viper Pro field computer. In order 
for this switch to work properly, a ‘Rate Bump’ (Rate +/-) value must be programmed for each product or control 
channel. See the Envizio Pro or Viper Pro operation manual for details on programming this feature.
For products in manual mode, holding the Increase/Decrease flow switch will open or close the control valve, 
increasing or decreasing the flow of product. See the Envizio Pro or Viper Pro Installation & Operation Manual 
for instructions on programming products or switching a product to manual mode.
Master Switch
The Switch Pro master switch toggles all section switches on or off. When the master switch is in the ON 
position, each section will function according to the corresponding section switch (see below for details). 
Toggle the master switch to OFF to turn off all boom sections manually.
Note:
If a remote master switch will be used with the Switch Pro, both master switches must be in the Off 
position to turn off booms. Toggling either the Switch Pro master or the remote Master will enable 
boom sections.
3-Way Selectable Section Switches
Each of the 10 section switches can be toggled individually to one of three possible positions:
•
ON - Manually control the section On. AccuBoom is disabled for this section and will not automatically turn 
this section Off based on AccuBoom or coverage maps.
•
ACCU - AccuBoom control over this section is enabled. AccuBoom will automatically control this section 
based on AccuBoom and coverage maps. Refer to the Envizio Pro or Viper Pro Installation & Operation 
Manual for more information on setting up and using AccuBoom features.
•
OFF - Manually control the section Off. This section will remain Off regardless of AccuBoom and coverage 
maps.
For sections not used by the Switch Pro, leave the corresponding section switch in the OFF position.
Note:
If auxiliary section switch hardware cannot be removed as described in the Preparation section on 
page 5, the auxiliary section switches must be in the Off position to allow Switch Pro to control 
boom functions properly.
Using AccuBoom Override
Switch Pro provides simple operation of the AccuBoom feature on the Envizio Pro or Viper Pro field computer.
•
AccuBoom control for each section is right at the operator’s finger tips.
•
AccuBoom Override can be enabled for individual sections using the 3-way selectable section switches.
Note:
To override AccuBoom across all sections, use the AccuBoom override feature on the field 
computer. Refer to the AccuBoom sections of the Envizio Pro or Viper Pro Installation & Operation 
Manual for more information on using AccuBoom and the AccuBoom override feature.