Seaward ARE 1557 User Manual
Page 16

ERT1557
Operating Instructions
- 16 -
6 Memory
Functions
6.1 Memory locations
All memory locations are allocated a unique index
number that is comprised of an identification code,
object identification number and measuring place.
Function code numbers are:-
1 = R
A
Two-point & Three-point test
2 = R
A
Clamp System Earth Resistance test
3 = R
A
Soil Resistivity test
Object identification numbers can be selected
between
001 and 999.
Measuring place can be selected between
0.0.1 and
9.9.9.
6.2 Storing results
6.2.1. Begin test measurement, the value of the
measured resistance is displayed on LCD.
6.2.2. To store the result displayed on the LCD press
the F4 (shift) + F2 (save) function keys to enter
the storage mode. As an indication the small
object identification number is displayed on the
LCD.
6.2.3. Press F1 (
D) or F2 (Ñ) function keys to select the
desired object identification number.
6.2.4. Press F4 (Shift) + F2 (
Ñ) function keys once
again to select the measuring place number.
6.2.5. Press F1 (
D) or F2 (Ñ) function keys to select the
desired measuring place.