beautypg.com

Scn60 service – Scotsman SCN60 User Manual

Page 37

background image

Compressor replacement.

1

Shut off water supply

2

Disconnect power supply or unplug unit

3

Uninstall unit and pull out as needed for side
and back access.

4

Remove back panel including drain and power
supply panels.

5

Remove side service panel.

6

Go through all steps to remove drain pump
and/or fan motor.

7

Remove drain hose from unit.

8

Add temporary refrigeration system access
valves to the discharge and suction sides of the
refrigeration system.

9

Recover the refrigerant.

10 Remove the four hair pins securing compressor

to chassis.

11 Disconnect wires, overload and and relay from

compressor.

12 Push back suction line insulation.

13 Unsweat the discharge and suction

connections at the compressor.

14 Remove the compressor from the unit.

15 Remove dryer from unit.

16 Attach permanent schrader access valves to

unit.

17 Attach dry nitrogen supply to access valves,

purge at about 1 lb pressure during brazing.

18 Install new dryer.

19 Install new compressor. Install at least 3 of the

hair pins to secure the compressor. The fourth
is optional.

20 Make all braze connections needed to seal

system.

21 Remove nitrogen supply. Evacuate system to

at least 300 microns.

22 Weigh in nameplate charge.

23 Reconnect all wires, components and panels

removed to access compressor.

24 Reinstall unit. Operate unit and test.

May 2011

Page 20

SCN60
Service

This manual is related to the following products: