Service Diagnosis

August 2011

Page 10

SCN60
Service

Problem

Likely Cause

Probable Solution

No ice, continued

Ice level sensor failure

With power on and Ice Making light on,
check connector, if secure jump the two
middle pins at J2 (bin stat) on the
controller together. Unit should start. If it
does, replace the sensor, if not, replace
the controller.

Auger motor on but compressor and fan
motor are off.

Restart unit. Check for power to
compressor and/or fan motor. If none,
replace controller.

Ice Making light blinking. Condition is
temporary, unit has been switched off.

Ice making light on, nothing operating.

May be in a restart window. See page 7.

Not keeping up, makes
ice but less than normal

Dirty condenser

Vacuum condenser fins

Air flow blocked

Check for vent blockage

Gravity drain restricted

Check drain, clear of restriction. Ensure
it has a proper air vent.

Pump drain slow

Check for proper pump switch operation
and drainage

Scale on evaporator and auger

Clean with scale remover. See
Maintenance section.

Torn door gasket, door does not close
tightly

Check gasket and door fit.

Makes ice but also an
unusual noise

Panels vibrating

Check panels, adjust fit, tighten screws

Fan blade rubbing

Check fan blade for foreign object.
Remove same. Check alignment.

Scale on evaporator and auger

Clean with scale remover. See
Maintenance section.

Drain pump cuts in and out.

Check valve failure, replace.

Tubes rubbing

Check for tube contact to panel or
another tube.

Unit in very cold conditions

Do not operate unit below limits

Water Leak

Drain tube off or cracked

Check/repair drain tube

Water inlet connection loose

Check/tighten connection

Water flows continuously

Float valve not shutting off

Check float, if stuck free it. If leaking by
when full, replace the valve.