beautypg.com

Scn60 service – Scotsman SCN60 User Manual

Page 24

background image

Performance and Technical Specs

Overall:

Refrigerant: 4.5 oz R-134a

Compressor: Hermetic, 700 BTUH

Condenser: Forced draft

Fan blade: 3 blade, 6 inch

Evaporator: Stainless steel tube, copper coil
jacketed

Metering device: Cap tube

Auger drive: output speed 11 RPM

Water valve: Float in reservoir

Drain pump: Magnetic drive, controlled by
pressure switch

Bin control: Ultrasonic

Electrical Components:

Compressor - 2.9 to 3.1 amps

Fan motor

Auger motor, amp draw .4 to .5amp

Drain pump motor

Drain pump switch

Controller

Transformer

Water sensor

Ice level sensor

Membrane switch assembly

Control Timers

Power interruption, time to restart after power
restored: 2 minutes

Auger motor overload, time to restart: 4
minutes

Auger motor overload, restart window: 60
seconds

Auger motor low current, time to restart: 20
minutes

Auger motor low current, restart window: 60
seconds

Clean cycle time: 40 minutes total.

Note: During the auger motor restart window times,
there is no visible indication that the unit is in a
restart mode.

Light Blink Information

All blink once and repeat every 2 seconds:
Auger motor overload

All blink twice and repeat every 2 seconds:
Auger motor low current

All blink once and repeat every 10 seconds,
controller failure.

Water light blinks red: water supply failure

Controller Reset:

Cycle power off and on

Diagnostic Codes: No diagnostic codes are kept

Time to Clean indicator light standard interval to
switch light on is 6 months, it can be changed to
once per year or disabled.

To Adjust:

1. From Off, press and hold the On/Off and Clean
Reset Buttons for 5 seconds.

2. Press and Hold the Clean Reset Button for 5
seconds, then press On/Off. Then press On/off
again to cycle thru the settings:

Ice Making

Water

Time to
Clean

6 months

On

Off

Off

1 year

Off

On

Off

Disabled

Off

Off

On

Light will automatically go out after a few seconds
of inactivity. Press Time To Clean to lock in the
new setting.

Quick reset of time to clean light: Press and hold
the Clean Reset button for 3 seconds.

May 2011

Page 7

SCN60
Service

This manual is related to the following products: