Sccg30 & sccp30 service manual – Scotsman SCCG30 User Manual
Page 24

Service Diagnosis
No Ice
Problem
Likely Cause
Probable Solution
No power to unit
Power disconnected
Check breaker or fuse. Reset or
replace, restart and check
Very long freeze cycle
Dirty condenser
Clean condenser
Restricted location, intake air too
hot or blocked
Eliminate restriction, have machine
moved
Evaporator thermostat not sensing
properly
Check thermostat
Spray jets dirty
Remove spray platform and clean
spray jets
Inlet water valve leaks through
during freeze
Check inlet water valve
Low on refrigerant
Check cube formation,
Connected to hot water
Check for bleed thru from / missing
check valve in building water
supply
Cannot make ice
Spray pump not pumping
Check pump motor
Fan motor not turning
Check fan motor, check fan blade
Pump hose disconnected
Check hose
Water leak
Check curtain, sump drain cap
Very low on refrigerant
Add access valve, add refrigerant
as a test. If unit makes ice, find and
correct leak.
Compressor not operating
Check compressor start
components
Check compressor voltage
Check compressor windings
Hot gas valve leaks through during
freeze
Check hot gas valve for hot outlet
during freeze
Compressor inefficient
Check compressor amp draw, if
low and all else is correct, change
compressor
September 2009
Page 23
SCCG30 & SCCP30
Service Manual