Installation: water & drain, Sccg30 & sccp30 service manual – Scotsman SCCG30 User Manual
Page 11

Installation: Water & Drain
Water Supply, all models: The recommended water
supply tubing is ¼ inch OD copper. Stainless steel
flex or reinforced PVC tube may also be used.
Install an easily accessible shut-off valve between
the supply and the unit. This shut-off valve should
not be installed behind the unit.
Note: Do not use self-piercing type valves.
1.
Remove the front service panel.
2.
Route the tubing
through the right
hole in the back to
the inlet water
solenoid valve inlet
at the front.
3.
Install a
compression fitting
on the tubing and
connect to the inlet
of the solenoid.
Note: Do NOT connect water to tubing at the back,
the water inlet connection is at the front.
Drains
There are two types of ice machine models, one
that drains by gravity and one that has an internal
drain pump.
Drain Pump Model drain installation
1. Locate the coil of 3/8” ID plastic drain tubing
secured to the back of the unit.
2. Route the plastic drain tube from the back of the
unit to the drain connection point.
IMPORTANT NOTE: Often an air gap is required by
local codes between the ice maker drain tube and
the drain receptacle.
September 2011
Page 10
SCCG30 & SCCP30
Service Manual
Back View, Drain Pump Model
Water Inlet
Tube (field
supplied)
Drain Tube,
Route to
building drain
Screw Securing Front
Service Panel
Connect Water Here