FOR THE PLUMBER

CONFORM TO ALL APPLICABLE CODES

Water Inlet

The recommended water supply is cold water.
Use 3/8" O.D. copper tubing, connect to the
3/8" male flare at the back of the cabinet.
Install a hand valve near the machine to
control the water supply.

Drains

There is one 3/4" FPT drain at the back of the
cabinet, the drain line is of the gravity type,
and 1/4 inch per foot fall is an acceptable pitch
for the drain tubing. There should be a vent at
the highest point of the drain line, and the
ideal drain receptacle would be a trapped and
vented floor drain. Use only 3/4" rigid tubing.
Storage Bin: A separate gravity type drain
needs to be run. Insulation of this drain line is
recommended.

WATER

INLET

3/8" FLARE

HAND

SHUT OFF

VALVE

CONNECT TO

COLD WATER

FIELD INSTALLED

FILTER

(OPTIONAL)

ICEMAKER DRAIN

3/4" FPT

BIN DRAIN

3/4" FPT

NM1250R