beautypg.com

Nm1250r, For the electrician, Fan relay kit – Scotsman NM1250R User Manual

Page 11

background image

FOR THE ELECTRICIAN

FAN RELAY KIT

To install the KCMR230 fan relay kit when
using (2) NM1250R icemakers and one 230
volt, two circuit remote condenser.
//////////////////////////////WARNING//////////////////////////
Do all wiring with electrical power OFF.
//////////////////////////////////////////////////////////////////////////
See the remote condenser nameplate for
current requirements to determine wire size to
be used for electrical hookup. Refer to wiring
diagram.
All external wiring should conform to the
national, state and local electrical codes.
Usually an electrical permit and services of a
licensed electrician will be required.
1. Mount the control box in a convenient
location.

2. Attach a solid earth ground wire to the
ground screw.
3. Route connecting wires from the first ice
maker junction box
(marked condenser fan) and connect it to the
KCMR230 terminal strip marked: NO. 1 ICE
MACHINE.
4. Route connecting wires from the second
machine junction box
(marked condenser fan) and connect it to the
KCMR230 terminal strip marked: NO. 2 ICE
MACHINE.
5. Route connecting wires from KCMR230
terminal strip marked: TO REMOTE FAN and
connect at the remote condenser junction box.

SUGGESTED

LOCATION

FOR KCMR230

CONTROL BOX

NM1250R

November, 1988

Page 11