Water Level
1. Unplug "water sen" connector from control
board.
2. Plug "water sen" connector from Scotsman
tester into circuit board.

a. Move "water" switch on tester to No Water

position. The No Water light on the circuit
board should go ON. If not, replace the circuit
board.

b. Move the "water" switch on the tester to the

Water position. The No Water light on the
board should go OFF. If not replace the circuit
board. If the light does go off, replace the
water level sensor.