FOR THE PLUMBER

CONFORM TO ALL APPLICABLE CODES

Water Inlet

Air Cooled Models: Connect a potable, cold water

supply to the 3/8" male flare at the back of the

cabinet. Install a hand valve near the machine to

control the water supply. 3/8" O.D. copper tubing is

recommended.

Water Treatment: In most areas, a water filter of

some type will be useful. In areas where the water

is highly concentrated with minerals the water

should be tested by a water treatment specialist,

and the recommendations of the specialist

regarding filtration and/or treatment should be

followed.

Water Cooled Models: Connect a separate 3/8"

O.D. copper line with a separate hand valve to

control it to the 3/8" FPT condenser inlet at the

back of the cabinet. The water pressure to all lines

must always be above 20 psig, and below 80 psig.

Drains

Air Cooled Models: There is one ¾ " FPT drain at

the back of the cabinet, the drain line is of the

gravity type, and ¼ inch per foot fall is an

acceptable pitch for the drain tubing. There should

be a vent at the highest point of the drain line, and

the ideal drain receptacle would be a trapped and

vented floor drain. Use only ¾ " rigid tubing.

Water Cooled Models: In addition to the above

mentioned drain, a separate condenser drain must

be installed. Connect it to the ½ " condenser drain

connection at the back of the cabinet.

NDE554 & NDE654

March 2000

Page 6

WATER INLET

CABINET

DRAIN

OPTIONAL

WATER

FILTER

WATER INLET

SHUT OFF

VALVE

VENTED

DRAIN TUBE

FLOOR DRAIN

WATER COOLED DETAIL

CONDENSER

WATER INLET

POTABLE

WATER INLET

CONDENSER

DRAIN

CABINET

DRAIN