For the installer – Scotsman NDE554 User Manual
Page 4

FOR THE INSTALLER
Location
After uncrating and inspection, the unit is ready for
installation. It is important that the machine be
installed in a location where it has enough space
above and behind it for service. Air cooled models
require a minimum of 6 inches to the left and right
of the machine for air circulation.
Machine Stand Installation
Tip the stand on its back and install the legs, return
the stand to the upright position. Adjust leg levelers
so that the stand does not “rock”.
Counter Top or Machine Stand Installation
The base of the icemaker-dispenser must be
sealed to the object it rests upon. Food grade
silastic sealant such as Scotsman part number
19-0529-01 is recommended.
Place a bead of the sealant on the machine stand
or counter top to match the outside edge of the
cabinet base and sink.
The icemaker-dispenser is heavy: use of a
mechanical hoist is recommended to lift it to the
height required to install it.
Follow the instructions packed with the machine
stand for proper connection to the dispenser. The
dispenser must be bolted to the machine stand
from inside the stand.
In both counter top and machine stand
installations, wipe off and neatly smooth any
excess sealant. Level the machine stand and
cabinet.
Unpack and install the sink brackets.
The hardware for the sink brackets is packed with
the sink. Screw one bolt into all four holes to tap
them BEFORE attaching the brackets. Attach the
brackets and place the sink assembly onto the two
sink brackets. Push down at the back to seat the
sink onto the brackets.
Press the sink onto the bead of sealant. Wipe off
and neatly smooth any excess sealant from under
the sink edge.
NDE554 & NDE654
March 2000
Page 4
SEAL THE
UNIT TO
THE
COUNTER
OR STAND