REMOVAL AND REPLACEMENT

Water Level
1. Unplug "water sen" connector from control
board.
2. Plug "water sen" connector from Scotsman
tester into circuit board.

a. Move "water" switch on tester to No Water

position. The No Water light on the circuit board
should go ON. If not, replace the circuit board.

b. Move the "water" switch on the tester to the

Water position. The No Water light on the board
should go OFF. If not replace the circuit board. If
the light does go off, replace the water level sensor.

LIGHT ON

WATER SENS

SWITCH TO

“NO WATER”

LIGHT OFF

SWITCH TO

“WATER”

ND550

December, 1988

Page 35