beautypg.com

Environmental limitations, Nd550, For the installer: environmental limitations – Scotsman ND550 User Manual

Page 3

background image

FOR THE INSTALLER: Environmental Limitations

Installation Limitations
This ice system is designed to be installed indoors,
in a controlled environment.

Minimum

Maximum

Air Temp

50

0

F.

100

0

F.

Water Temp

40

0

F.

100

0

F.

Water Pressure

20 PSI

80 PSI

Voltage

104

126

Operating the machine outside of the above
limitations, or outdoors, is potentially damaging to
the machine; also it is misuse of the machine,
which may void the warranty.
Scotsman Ice Systems are designed and
manufactured with the highest regard for safety
and performance. They meet or exceed the
standards of UL, NSF, and CSA.
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any part and/or other components not
specifically approved by Scotsman.
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and design are subject to change
without notice.
Water Limitations
An ice machine is a food manufacturing plant; it
takes a raw material, water, and turns it into a food
product, ice. The purity of the water is very
important in obtaining pure ice and in maximizing
product life. This section is not intended as a
complete resource for water questions, but it does
offer these general recommendations:
1. Filter the water used to produce ice. That is the
water going to the "potable" water connection.
Water filters vary greatly in ability and function.
Install one that filters out suspended solids to a
dimension of 5 microns or smaller. The finer the
filter the better, but finer filters will clog sooner
than course ones. It may be necessary to add a
course filter ahead of the fine filter to prolong filter
life.
2. Check with a water treatment specialist for a
water test, and recommendations regarding filters
and treatment.
Service Limitations
Do not install in a location where the top of the
machine is within 6" of a fixed ceiling. Do not install
air cooled models in a location where there is less

than 6" clearance to the left and right of the
cabinet.

WALL

CUT AWAY

CEILING

CUT AWAY

6" SPACE

FOR AIR

(AIR COOLED)

SPACE

ABOVE

FOR

SERVICE

6" SPACE

FOR AIR

(A/C)

SPACE

FOR

UTILITIES

ND550

December, 1988

Page 3

This manual is related to the following products: