For The Plumber

Drains:

The dispenser requires a gravity drain. The pitch

on the drain tubes must be at least 1/4 inch fall per

foot of horizontal run. On long horizontal runs, a

vent at the back of the cabinet will improve

draining, and is recommended.

There are two drains to connect: A sink drain, a

7

8

plastic tube; and the bin drain, a

5

8

” plastic tube.

Install rigid tubing between the machine and the

building drain. Route the drains separately to the

building drain.

Water supply:

Connect cold, potable water to the machine. A

hand valve near the location is recommended. A

water filter is also a good idea.

Follow all local codes.

FDE474

March 2000

Page 5

FOLLOW ALL APPLICABLE LOCAL, STATE

AND NATIONAL CODES

Strainer or

Filter

Water Inlet Fitting

(Inside Cabinet)

Sink Drain

Bin and Reservoir

Overflow Drains

Water Supply

Building Drain

(Typical)