beautypg.com

Fde474, Bearings, water seal and auger – Scotsman FDE474 User Manual

Page 25

background image

Bearings, Water Seal and Auger

1. Disconnect electrical power.

2. Shut off the water supply.

3. Remove the top panel.

4. Remove the side panels.

5. Drain the reservoir and evaporator.

6. Remove foam cap from the top of the

evaporator.

7. Remove the two permagum plugs from the side

of the evaporator.

8. Pull up on the ring to lift the auger out of the

evaporator.

If the auger will not lift out:

1. Remove snap ring holding bearing cover to

breaker.

2. Remove bearing cover.

3. Unscrew bolt holding bearing to auger.

4. Thread in a threaded rod and weight or

slide-hammer puller into the auger.

5. Use the threaded rod & weight or slide hammer

puller to remove the auger.

Or

1. Remove three cap screws holding evaporator to

the adapter stand.

2. Lift evaporator up slightly and tip the bottom out

to expose the splined end of the auger.

3. Use a plastic mallet or dead-blow hammer to tap

the bottom of the auger and force the auger up. Do

NOT damage the splines of the auger or the auger

will have to be replaced.

If the auger is “frozen” to the bottom bearing, do

not force the bottom bearing thru the evaporator.

1. Remove three cap screws holding evaporator to

the adapter stand.

2. Lift evaporator up slightly and tip the bottom out

to expose the splined end of the auger.

3. Remove snap ring holding bearing cover to

breaker.

4. Remove bearing cover.

5. Unscrew bolt holding bearing to auger.

6. Screw a length of threaded rod or a shoulder

screw into the auger.

7. Tap on the end of the threaded rod to push the

auger out of the bottom of the evaporator.

8. Replace the bearings and water seal. Replace

the auger if the splines are damaged. Replace the

evaporator if more than 1/3 of the vertical rifle

grooves are gone. Sand or hone and sand the

inside of the evaporator if mineral build up is

heavy.

FDE474

March 2000

Page 25

Snap Ring

Cap

Bolt

Washer

Top Bearing

Breaker

Auger

Water Seal

Coupling

Rotating parts hazard.

Disconnect Electrical

Power Before

This manual is related to the following products: