Status List

Press and release the down arrow to underline the S in Status.
Press and release the Enter button to see:

Warranty Start: The display will show the warranty start date after 24 hours of
run time. Press and release the Down arrow to see:

Relay Voltage: Voltage supplied to the relays. Press and release the Down
arrow key to see:

Board Voltage: Voltage supplied to operate the controller. Press and release
the Down arrow key to see:

Auger Motor Current: Current draw of the auger drive motor. Press and
release the Down arrow key to see:

Auger Motor Trip Current: Maximum allowed amp draw. Press and release
the Down arrow key to see:

Auger Motor Strikes: Number of times auger motor has currently exceeded
the amp draw setpoint. Press and release the Down arrow key to see:

Ice Making Sensed: Has the controller sensed ice making? Press and release
the Down arrow key to see:

Ice Making Strikes: Number of times the controller has not sensed ice falling
in the chute. Press and release the Down arrow key to see:

Freeze Timer: Current compressor on time in minutes. Press and release the
Down arrow key to see:

KVS Level: Distance in inches the ice level control system has measured from
the sensor to the top of the ice. Press and release the Down arrow key to see:

KVS Level Setpoint: Distance in inches the ice level system will maintain as a
maximum ice level. Press and release the Down arrow key to see:

Power Interrupt Counter: Number of times power has been interrupted to the
machine. Press and release the Down arrow key to see:

Bin Stat Input: Shows Closed if no bin thermostat is attached or if one is
attached and is Closed. Shows open only if there is a bin thermostat attached
and it is open, which stops ice making. When done with Status, press and
release the ESC button.

August 2011

Page 7

NB0622, NB0922, FB1222, NB1322
Information Display

Relay Voltage:
240 VAC

Board Voltage:
14 VAC

Auger Mot Current
1.8 Amps AC

Aug Mot Trip Curr
3.0 Amps AC

Ice Making Sensed
Yes

Ice Making Strikes
0

Freeze Timer:
00:00

KVS Level
00:00

KVS Level Setpoint
0

Pwr Interrupts
0

Bin Stat
Opem

Adv Faults
Status

Auger Mot Strikes
0

Warranty Start:
Starts at 24HRS