Advance Fault Definitions - Flaker or Nugget

Self-Test Failure

The controller checks for proper operation at power up. If the check shows a problem, this warning or
fault will be displayed.

No Ice Pending

The controller monitors ice making using the photo eyes. If falling ice is not sensed by the photo-eyes,
and if it is NOT the third consecutive time it has occurred, this warning or fault will be displayed.

No Ice Strikeout

If the controller fails to sense ice for a third consecutive time, this warning or fault will be displayed and
the machine will be shut down.

Auger High Load Pending

The controller monitors the current used by the auger drive motor. If the current exceeds the limit, and if
it is NOT the third consecutive time that it has, this warning or fault will be displayed.

Auger High Load Strikeout

If the auger motor draws too much current for a third consecutive time, this warning or fault will be
displayed and the unit will be shut down.

No Water

If the water level sensor is dry or the water is too pure, this warning or fault will be displayed, and the unit
will be shut off.

Refrigeration Pressure Too High/Low

There are two pressure switches on the machine, if either one opens due to an over or under pressure
condition, the controller will display this fault or warning.

August 2011

Page 6

NB0622, NB0922, FB1222, NB1322