What to do before calling for service
Normal Operation:
Ice
The machine will make either flaked or nugget ice,
depending upon the model. The ice will be
produced continuously until the bin is full. It is
normal for a few drops of water to occasionally fall
with the ice.
Heat
Air cooled models will generate heat, and it will be
discharged into the room.
Noise
The ice machine will make noise when it is in ice
making mode. The compressor and gear reducer
will produce sound. Air cooled models will add fan
noise. Some ice making noise could also occur.
These noises are all normal for this machine.
Reasons the machine might shut itself off:
•
Lack of water.
•
Does not make ice
•
Auger motor overload
•
High discharge pressure.
•
Low refrigeration system pressure.
•
Controller self test failure.
Check the following:
1. Has the water supply to the ice machine or
building been shut off? If yes, the ice machine will
automatically restart within minutes after water
begins to flow to it.
2. Has power been shut off to the ice machine? If
yes, the ice machine will automatically restart when
power is restored.
Machine Beeps:
If the machine has detected a condition requiring a
shut down, it will blink the Status Light and emit a a
beep once every second. To stop the beep, push
Off or reset the machine.
To Manually Reset the machine.
•
Push and release the Off button.
•
Push and release the On button.
To Shut the Machine Off:
Push and hold the Off button for 3 seconds or until
the machine stops.
August 2011
Page 15
NB0622, NB0922, FB1222, NB1322
Installation and Use
Indicator Lights & Their Meanings
Power
Status
Water
De-Scale &
Sanitize
Light
Actions
Steady Green
Normal
Normal
-
-
Blinking Green
Self Test
Failure
Switching on or off.
When Smart-Board used,
machine attention
recommended.
-
-
Blinking Red
-
Diagnostic shut down
Lack of water
-
Yellow
-
-
-
Time to descale
and sanitize
Blinking Yellow
-
-
-
In Cleaning Mode
Light Off
No power
Switched to Off
Normal
Normal
All Blinking
Unit is remotely locked out - check with leasing company