CB0522 through CB1030
Information Display

Status List

Press and release the down arrow to underline the S in Status. Press and

release the Enter button to see:

Warranty Start shows "Starts at 24HRS run time"; after 24 hours of run
time, shows warranty start date.

Discharge Temp in degrees F., Then press and release the Down arrow
key to see:

Sump Temp in degrees F. Then press and release the Down arrow key to
see:

Board Voltage - from the transformer. Then press and release the Down
arrow key to see:

Bin Level number. Displays level currently sensed. Then press and release
the Down arrow key to see:

Bin set point: Displays level currently set. Then press and release the
Down arrow key to see:

Freeze Timer: Freeze time. Press and release the Down arrow key to see:

Harvest Timer:: Harvest time. Then press and release the Down arrow key
to see:

Freeze Counter: Then press and release the Down arrow key to see:

Water Quality.: Measurement of the conductivity of the reservoir water.
Typically between 20 and 60, lower numbers mean higher mineral content.
Then press and release the Down arrow key to see:

Flush Used: The WaterSense system selected this purge setting. Reads
255 if sump empty. Then press and release the Down arrow key to see:

Long Freeze Strike: Long Freeze Strike number. Number of long freeze
errors in memory. Then press and release the Down arrow key to see:

Long Harvest Strike: Long Harvest Strike number: Number of long harvest
errors in memory. Then press and release the Down arrow key to see:

Min Frz Strike: Minimum freeze strike number Then press and release the
Down arrow key to see:

Pwr Interrupts: Number and time of power interruptions. Then press and
release the Down arrow key to see:

Bin Stat: Open or Closed. Open is normal when no bin thermostat is
attached or there is no ice on a thermostat. Then press and release the
Down arrow key to see:

Disch Frz Set: In degrees F. Shows the discharge temperature recorded as
a set up number. The set up number is used for determining how long the
fan is off at the end of the freeze cycle.

Adv Faults

Status

Discharge Temp:

157

Sump Temp:

38

Board Voltage:

14

Bin Level:

13

Bin Setpoint:

9

Freeze Timer:

00:00

Harvest Timer:

00:00

Freeze Counter:

0

Water Quality:

0

Flush Used:

0

Long Frz Strike:

0

Long Hrv Strike:

0

Min Frz Strike:

0

Pwr Interrupts:

0

Bin Stat:

Open

Disch Frz Set:

0

Warranty Start:

Starts at 24 HRS