beautypg.com

Scotsman CB0522 User Manual

Page 27

background image

Advanced Fault Definitions

Self test failure

The controller checks for proper operation at power
up. If the check shows a problem, this warning or
fault will be displayed.

Long Freeze Pend

If the ice machine fails to make ice within the
maximum time limit, the controller will note that and
display this warning or fault while it is attempting
another freeze cycle.

Long Freeze Strikeout

If the ice machine fails to make ice within the
maximum time limit for a third consecutive time,
this warning or fault will be displayed and the
machine will be shut down.

Long Harv Pend

If the ice machine fails to release ice within the
maximum time limit, the controller will note that and
display this warning or fault while it is attempting
another freeze cycle

Long Harvest Strikeout

If the ice machine fails to release ice within the
maximum time limit for a third consecutive time,
this warning or fault will be displayed and the
machine will be shut down.

Check Water

If the water level sensor does not sense a full
reservoir during the maximum time limit, this
warning or fault will be displayed. The machine will
automatically attempt to fill with water.

High Temp Error

If the discharge temperature exceeds 250 degrees
at any time, the controller will shut the machine
down and display this warning or fault.

Sump Temp Sensor

The water temperature sensor's resistance varies
with the water temperature. If the resistance is
beyond what the sensor's capability is, this warning
or fault is displayed.

Discharge Temp Sensor

The discharge temperature sensor's resistance
varies with the refrigerant temperature. If the
resistance is beyond what the sensor's capability
is, this warning or fault is displayed.

Min Freeze Pend

If the controller senses finished ice thickness
before the minimum freeze time has elapsed, this
warning or fault will be displayed.

Minimum Freeze Strikeout

If the controller senses finished ice thickness
before the minimum freeze time has elapsed three
cycles in a row, this warning or fault will be
displayed if the machine and the machine will be
shut down.

CB0522 through CB1030
Information Display

August 2011

Page 27

This manual is related to the following products: