background image

Adjustments

Bridge Thickness - For the Service Tech Only

1.

Push and hold Off till the machine stops.

2.

Remove evaporator cover.

3.

Remove curtain.

4.

Use a hex wrench and rotate the bridge
thickness adjustment screw in 1/8 turn
increments CW to increase bridge thickness.
Rotate CCW to decrease bridge thickness.

Caution: Do not make the bridge too thin or the
machine will not harvest properly. Bridge thickness
adjustments are not covered by warranty.

5.

Return curtain and evaporator cover to their
normal positions.

6.

Push and release the On button. Check next
harvest of ice. Repeat steps 1-6 if needed.

Water Purge Setting

The water purge is factory set to the automatic
position, suitable for most water conditions. The
setting can be changed to one of 5 manual settings
or left on automatic.

Purge
setting

1 - Minimum

2 -
Moderate

3 - Standard

4 - Heavy

5 - Maximum

A - Automatic

Water
Type

RO water or
equivalent

Low TDS
non - RO
water

Use for
typical water

High TDS
water

Very High TDS
water

Any with
conductivity not less
than 10
microSiemens/cm

To set:

1.

Switch the machine OFF by holding the Off
button in until a number or the letter

A shows

on the display.

2.

Press and release the On button repeatedly
until the number on the display corresponds to
the desired setting.

3.

Press and release the Off switch again to
return to the normal control state.

August 2011

Page 12

CB0522 through CB1030
Air Cooled User Manual

Bridge Thickness Adjustment Mechanism

Ice Bridge Thickness Measurement

Adjustment
Screw

Too Big

Too Small

Just Right

1/8-3/16"

bridge