Read and write communication address (not IP address):

Symbol

Byte

Definition

Note

CMD

1

0x6A (Regulate other function)

DAT1

1

0x20(write) 0x21(read) Local address

DAT2

1

0~99(Local address) 0 means
broadcast address

DAT3

1

0(no use)

DAT4

1

0(no use)

Local address is default for 0

LOGO Information Setting:

Symbol

Byte

Definition

Note

CMD

1

0x68

DAT1

1

0xf2

DAT2

1

0(no use)

DAT3

1

0(no use)

DAT4

1

0(no use)

PC send: +128BYTE (block data) +1BYTE

(checksum)

Lower PC reply:

Block data content: 0-15 customer and manufacturer information

20-35 customer and device information

Information not reach 16 bytes will be filled by '\ 0'

LOGO Display Parameters Setting:

Symbol

Byte

Definition

Note

CMD

1

0x68

DAT1

1

0xf3

DAT2

1

1/0 Open/Close LOGO display

DAT3

1

1/0 Display/Cancel display customer
LOGO

DAT4

1

1-10 boot LOGO display time (second)

Customer LOGO Display Parameters:

Symbol

Byte

Definition

Note

CMD

1

0x68

DAT1

1

0xf0