Media feeding problems, Problem, Possible cause – Rena T-250 User Manual
Page 18: Feeding doubles, Media not properly fanned before loading, Nested media, Separator fingers worn, Media not feeding, Side guides too tight, Glazed or dirty feed rollers

TROUBLESHOOTING
Media Feeding Problems:
Problem Possible
Cause
Feeding Doubles
Media not properly fanned before loading.
Nested Media.
Reduce the distance between the separator
fingers and the feed roller.
Separator Fingers worn.
Media Not Feeding
Media not properly fanned before loading.
Side Guides too tight
Increase the distance between the separator
fingers and the feed roller.
Glazed or dirty feed rollers.
Feed Rollers worn.
Media Opening as it Feeds
Too much friction at the separation point.
Increase the distance between the separator
fingers and the feed roller by using 1-1/2
times the material thickness to set the
Metering Bracket.
Skewing
Media Side Guides too loose.
Metering Bracket/Separators not set evenly.
Separator Fingers or Feed Rollers worn.